R-410A is a near-azeotropic HFC refrigerant blend used in air conditioning, heat pump, and selected medium-temperature refrigeration equipment designed specifically for R-410A.
R410A is a near-azeotropic HFC refrigerant used in air conditioning, heat pump, chiller and selected medium-temperature refrigeration equipment designed specifically for R410A. This 25 lb cylinder is suitable for professional service of compatible residential and commercial systems.
Use R410A only in equipment specifically designed for R410A. It operates at substantially higher pressures than R22 and must not be used in R22, R32, R454B or other systems. Verify the equipment nameplate before purchase.

| Refrigerant | R410A refrigerant blend |
| Composition | 50% R-32 + 50% R-125 |
| Net Weight | 25 lb (11.3 kg) |
| Purity | ≥ 99.80% |
| Cylinder | Pressure-resistant steel |
| Molecular formula | 50% R-32 + 50% R-125 |
| Molecular weight | 72.58 |
| Boiling point @ 1 atm | -51.6°C |
| Working pressure @ 25°C | 1.65 MPa |
| Liquid density | 1062 kg/m³ |
| Critical temperature | 72.13°C |
| Critical pressure | 4.926 MPa |
| Water content | ≤ 0.001% |
| Acidity | ≤ 0.0001% |
| Evaporation residue | ≤ 0.01% |
| Appearance | Colorless and clear |
| Odor | Odorless |
Return approval and specialized carrier requirements may apply. Return shipping costs are the customer's responsibility.
Use R410A only in compatible air-conditioning and heat-pump equipment designed for its operating pressure.
R410A service requires equipment rated for the refrigerant's pressure range and should be performed by qualified HVAC personnel.
The cylinder contains 25 lb (11.3 kg) net weight of R410A. Verify the label, valve, and cylinder condition before use.
R410A should normally be removed from the cylinder in the liquid phase and introduced according to the equipment manufacturer's service procedure.
Stationary-system refrigerant sales and service are subject to EPA Section 608 requirements.
Not sure whether your system uses R410A? Send support a photo of the outdoor-unit nameplate before ordering.
Use R410A only in systems designed and labeled for R410A. It operates differently from R22 and must not be mixed with R22, R32, R454B, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.
R410A refrigerant blend is intended for compatible R410A air-conditioning, heat-pump, and HVAC equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.
The cylinder contains 25 lb (11.3 kg) net weight of R410A refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.
No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.
R410A is a high-pressure refrigerant. Service requires appropriate recovery and charging equipment and should be performed by a qualified HVAC professional. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.
Shipping is free on U.S. orders. Orders ship from the United States within 24 business hours, and estimated delivery is 2–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.
Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.
A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer's responsibility, and refunds are issued after inspection.
Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.
Great price and fast shopping.
This is the only place to go for freon!
They can totally be trusted. This is not one of those fly-by-night stores. They might have some misspellings in their advertisements but that does not mean they're not honest. They just don't know how to spell. These guys are fantastic. I've been using them for years and they always have great product and great service.
Great price super fast shipping quality products thank you
Very fast delivery, well packaged. Flawless transaction.