Free Shipping on all U.S. orders • EPA-compliant, factory-sealed refrigerants • 30-day returns
SHOPRON

22 lb R454B A2L Refrigerant Cylinder for HVAC & Heat Pumps

$280.00 USD$59.00 USDSave $221.00
Shipping calculated at checkout.
Package protection powered by XCOTTON®

R454B is an HFO/HFC refrigerant blend developed for new air conditioning, heat pump and chiller equipment designed as a lower-GWP alternative to R410A. This 22 lb cylinder is intended for professional service of compatible R454B systems.

Buy in bulk and get a discount!The more you buy, the more you save.
Buy 5 and get $50.00 discount!
Accepted payments
VISAAMEXDISCOVERPayPal Pay
Secure checkout powered by Stripe
Free U.S. shipping
AHRI-700 certified
30-day returns

Product Overview

R454B is an HFO/HFC refrigerant blend developed for new air conditioning, heat pump and chiller equipment designed as a lower-GWP alternative to R410A. This 22 lb cylinder is intended for professional service of compatible R454B systems.

Key Benefits

  • 22 lb R454B refrigerant cylinder
  • For new equipment designed and labeled for R454B
  • Suitable for compatible air conditioning and heat pumps
  • Used in approved reversible chillers and HVAC systems
  • A2L refrigerant intended for trained professionals

Compatibility Notice

Use R454B only in equipment specifically designed for R454B. Do not charge it into an existing R410A system unless the equipment manufacturer explicitly approves the application. Follow all A2L handling, ventilation and tool requirements.

22 lb R454B A2L Refrigerant Cylinder for HVAC & Heat Pumps in use
22 lbNet Weight
≥ 99.80%Purity
0ODP
466GWP

Key Specifications

RefrigerantR454B refrigerant blend
Molecular FormulaRefrigerant blend
Net Weight22 lb (10 kg)
Purity≥ 99.80%
CylinderPressure-resistant steel
For professional air-conditioning, heat pump, and HVAC service.

Full Technical Data

Molecular formulaRefrigerant blend
Molecular weight62.60
Boiling point @ 1 atm-50.50°C
Working pressure @ 25°C1.571 MPa
Liquid density985 kg/m³
Critical temperature78.10°C
Critical pressure5.267 MPa
Water content≤ 0.001%
Acidity≤ 0.0001%
Evaporation residue≤ 0.01%
AppearanceColorless and clear
OdorOdorless
FreeU.S. Shipping
Within 24hDispatch
2–5 DaysEstimated Delivery
U.S. WarehouseShips From

Shipping

  • Free shipping on all U.S. orders
  • Ships within 24 business hours
  • Estimated delivery: 2–5 business days
  • Ships from the United States
  • Tracking provided after dispatch
Shipping Calculation
1 Cylinder
Free
2 Cylinders
Free
3 Cylinders
Free

Returns

  • 30-day return request window
  • Unused and unopened cylinders only
  • Original condition and packaging required
  • Contact support before returning regulated goods
  • Refunds issued after inspection
Hazardous Material Notice

Return approval and specialized carrier requirements may apply. Return shipping costs are the customer's responsibility.

R454B product notice

Important R454B Product Information

R454B is a high-pressure refrigerant blend for equipment specifically designed and labeled for R454B. Review these requirements before ordering.

Use R454B only in equipment engineered and approved for this refrigerant and its A2L safety requirements.

  • Do not add R454B to an R410A, R32, R22, or other system.
  • R454B is not a universal drop-in replacement.
  • Follow the manufacturer's charge limit and commissioning procedure.

R454B is mildly flammable and requires trained handling, ventilation, leak checks, and controlled service conditions.

  • Keep flames, sparks, and hot surfaces away from the work area.
  • Use A2L-rated recovery, evacuation, leak-detection, and charging equipment.
  • Follow applicable room-size and charge-limit requirements.

The cylinder contains 22 lb (10 kg) net weight of R454B blend. Verify the product label and cylinder condition before use.

  • Keep the cylinder upright and secured.
  • Do not use a damaged, leaking, or altered cylinder.
  • Confirm the valve connection and required quantity before ordering.

R454B should normally be transferred from the cylinder in the liquid phase and charged according to the equipment manufacturer's instructions.

  • Use a metering method that prevents liquid slugging.
  • Do not mix R454B with another refrigerant.
  • Perform required leak checks before returning equipment to service.

Stationary-system refrigerant purchase and service are subject to EPA Section 608 requirements.

  • The purchaser must be, or employ, an appropriately certified technician.
  • Store in a cool, dry, ventilated area away from ignition sources.
  • Review the Safety Data Sheet and Shipping & Returns tab before ordering.

Not sure whether your equipment uses R454B? Send support a clear photo of the equipment nameplate before ordering.

Frequently Asked Questions

Use R454B only in equipment specifically designed and labeled for R454B. It is not interchangeable with R410A, R32, R22, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.

R454B refrigerant blend is intended for compatible R454B air-conditioning, heat-pump, and HVAC equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.

The cylinder contains 22 lb (10 kg) net weight of R454B refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.

No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.

R454B is an A2L refrigerant with lower flammability. Qualified professionals should use A2L-rated tools, ventilation, leak-detection, recovery, and charging procedures. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.

Shipping is free on U.S. orders. Orders ship from the United States within 24 business hours, and estimated delivery is 2–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.

Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.

A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer's responsibility, and refunds are issued after inspection.

Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.

You may also need

Related products

Customer Reviews

4.67 out of 5Based on 3 reviews
2
1
0
0
0
3 reviews
08/19/2026
Walter O. Verified Buyer
Awesome prices, speed, and matched a competitor's price

Had purchased R22, R454B, and R410A, paid for the order, and found the R454B $70 cheaper from a competitor, so I emailed asking them to match it or cancel. They matched it and credited the difference back. Stand-up move, 5 stars for sure.

08/15/2026
Cynthia B. Verified Buyer

Was delivered in the timeline provided and exactly what I ordered

08/10/2026
Harold N. Verified Buyer
R454B refrigerant

It was delivered promptly and undamaged, haven't used it yet, but looks good so far.