25 lb R449A Refrigerant Cylinder for Commercial Refrigeration

$280.00 USD$59.00 USDSave $221.00
Shipping calculated at checkout.
Package protection powered by XCOTTON®

R449A is an HFO/HFC blend used in low- and medium-temperature commercial and industrial refrigeration. This 25 lb cylinder is suitable for approved new equipment and retrofits replacing R404A, R507A, R22 or selected R407-series refrigerants.

Buy in bulk and get a discount!The more you buy, the more you save.
Buy 5 and get $50.00 discount!
Accepted payments
VISAAMEXDISCOVERPayPal Pay
Secure checkout powered by Stripe
Free U.S. shipping
AHRI-700 certified
30-day returns

Product Overview

R449A is an HFO/HFC blend used in low- and medium-temperature commercial and industrial refrigeration. This 25 lb cylinder is suitable for approved new equipment and retrofits replacing R404A, R507A, R22 or selected R407-series refrigerants.

Key Benefits

  • 25 lb R449A refrigerant cylinder
  • For low- and medium-temperature refrigeration
  • Suitable for compatible commercial and industrial systems
  • Used in approved walk-ins, cold storage and food service
  • A1-classified refrigerant for professional service

Compatibility Notice

Use R449A only in equipment designed for R449A or in a manufacturer-approved retrofit. Do not mix it with R404A, R507A, R22 or another refrigerant. Confirm lubricant, controls and operating settings before conversion.

25 lb R449A Refrigerant Cylinder for Commercial Refrigeration in use
25 lbNet Weight
≥ 99.80%Purity
0ODP
1397GWP

Key Specifications

RefrigerantR449A refrigerant blend
Molecular FormulaRefrigerant blend
Net Weight25 lb (11.3 kg)
Purity≥ 99.80%
CylinderPressure-resistant steel
For professional commercial refrigeration and low-temperature systems.

Full Technical Data

Molecular formulaRefrigerant blend
Molecular weight87.20
Boiling point @ 1 atm-46.00°C
Working pressure @ 25°C1.275 MPa
Liquid density1113.3 kg/m³
Critical temperature81.50°C
Critical pressure4.45 MPa
Water content≤ 0.001%
Acidity≤ 0.0001%
Evaporation residue≤ 0.01%
AppearanceColorless and clear
OdorOdorless
FreeU.S. Shipping
Within 24hDispatch
2–5 DaysEstimated Delivery
U.S. WarehouseShips From

Shipping

  • Free shipping on all U.S. orders
  • Ships within 24 business hours
  • Estimated delivery: 2–5 business days
  • Ships from the United States
  • Tracking provided after dispatch
Shipping Calculation
1 Cylinder
Free
2 Cylinders
Free
3 Cylinders
Free

Returns

  • 30-day return request window
  • Unused and unopened cylinders only
  • Original condition and packaging required
  • Contact support before returning regulated goods
  • Refunds issued after inspection
Hazardous Material Notice

Return approval and specialized carrier requirements may apply. Return shipping costs are the customer's responsibility.

R449A product notice

Important R449A Product Information

R449A is a high-pressure refrigerant blend for equipment specifically designed and labeled for R449A. Review these requirements before ordering.

R449A is used in medium- and low-temperature refrigeration, but it is not a top-off replacement for another refrigerant.

  • Do not add R449A on top of R404A, R507, or another refrigerant.
  • Confirm compressor, valve, control, seal, and lubricant compatibility.
  • Follow the equipment or retrofit manufacturer's instructions.

Retrofit and service work should be completed by appropriately EPA Section 608-certified personnel.

  • Recover the original refrigerant completely.
  • Make required component and control adjustments.
  • Record R449A and the final charge on the equipment label.

The cylinder contains 25 lb (11.3 kg) net weight of R449A. Inspect the label, valve, seal, and package before use.

  • Keep the cylinder upright and secured.
  • Do not use a damaged or leaking cylinder.
  • Confirm the required quantity and connection before ordering.

R449A should be transferred from the cylinder in the liquid phase and charged by weight.

  • Meter liquid safely to prevent compressor damage.
  • Use appropriate dew-point and bubble-point data.
  • Verify superheat, subcooling, controls, and discharge temperature.

Commission the converted system according to the retrofit guide and follow the Safety Data Sheet.

  • Check operating limits and discharge temperature.
  • Store the cylinder in a cool, dry, ventilated area.
  • Review the Shipping & Returns tab before ordering.

Planning an R449A conversion? Send support the current refrigerant, compressor model, application, and target temperature.

Frequently Asked Questions

Use R449A only when specified by the equipment manufacturer or an approved retrofit plan. It is not interchangeable with R404A, R448A, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.

R449A refrigerant blend is intended for compatible commercial refrigeration and low-temperature equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.

The cylinder contains 25 lb (11.3 kg) net weight of R449A refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.

No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.

A qualified refrigeration professional should confirm system compatibility, lubricant, controls, and approved service procedures before installation or charging. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.

Shipping is free on U.S. orders. Orders ship from the United States within 24 business hours, and estimated delivery is 2–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.

Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.

A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer's responsibility, and refunds are issued after inspection.

Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.

You may also need

Related products

Customer Reviews

No reviews yet for this product.