R407A is a zeotropic HFC blend used in compatible medium- and low-temperature refrigeration systems. This 25 lb cylinder is suitable for professional service of new equipment and approved retrofits replacing R404A or R507A.

Buy in bulk and get a discount!The more you buy, the more you save.
Buy 5 and get $50.00 discount!
Accepted payments
VISAAMEXDISCOVERPayPal Pay
Secure checkout powered by Stripe
Free U.S. shipping
AHRI-700 certified
30-day returns

Product Overview

R407A is a zeotropic HFC blend used in compatible medium- and low-temperature refrigeration systems. This 25 lb cylinder is suitable for professional service of new equipment and approved retrofits replacing R404A or R507A.

Key Benefits

  • 25 lb R407A refrigerant cylinder
  • For medium- and low-temperature refrigeration
  • Suitable for compatible supermarket refrigeration
  • Used in approved food storage and transport systems
  • Designed for professional refrigeration maintenance

Compatibility Notice

Use R407A only in equipment labeled for R407A or in a manufacturer-approved conversion. Do not mix R407A with R404A, R407C, R507A or another refrigerant. System controls and components must be checked before retrofit.

25 lb R407A Refrigerant Cylinder for Commercial Refrigeration in use
25 lbNet Weight
≥ 99.80%Purity
0ODP
2107GWP

Key Specifications

RefrigerantR407A refrigerant blend
Molecular FormulaRefrigerant blend
Net Weight25 lb (11.3 kg)
Purity≥ 99.80%
CylinderPressure-resistant steel
For professional commercial refrigeration and low-temperature systems.

Full Technical Data

Molecular formulaRefrigerant blend
Molecular weight90.10
Boiling point @ 1 atm-45.50°C
Working pressure @ 25°C1.18 MPa
Liquid density1090 kg/m³
Critical temperature86.20°C
Critical pressure4.63 MPa
Water content≤ 0.001%
Acidity≤ 0.0001%
Evaporation residue≤ 0.01%
AppearanceColorless and clear
OdorOdorless
FreeU.S. Shipping
Within 24hDispatch
2–5 DaysEstimated Delivery
U.S. WarehouseShips From

Shipping

  • Free shipping on all U.S. orders
  • Ships within 24 business hours
  • Estimated delivery: 2–5 business days
  • Ships from the United States
  • Tracking provided after dispatch
Shipping Calculation
1 Cylinder
Free
2 Cylinders
Free
3 Cylinders
Free

Returns

  • 30-day return request window
  • Unused and unopened cylinders only
  • Original condition and packaging required
  • Contact support before returning regulated goods
  • Refunds issued after inspection
Hazardous Material Notice

Return approval and specialized carrier requirements may apply. Return shipping costs are the customer's responsibility.

R407A product notice

Important R407A Product Information

R407A is a high-pressure refrigerant blend for equipment specifically designed and labeled for R407A. Review these requirements before ordering.

R407A is commonly used in commercial refrigeration, but equipment compatibility must be confirmed before charging.

  • Do not add R407A directly on top of R22, R404A, or another refrigerant.
  • A retrofit may require oil, seal, control, and expansion-device changes.
  • Record the completed refrigerant conversion on the equipment label.

Stationary refrigeration work should be performed by appropriately EPA Section 608-certified personnel.

  • Recover the existing charge completely before conversion.
  • Evacuate, leak-test, and weigh in the specified charge.
  • Do not intentionally vent refrigerant.

The cylinder contains 25 lb (11.3 kg) net weight of R407A. Inspect the label, valve, seal, and cylinder before use.

  • Keep the cylinder upright and secured.
  • Do not use a damaged or leaking cylinder.
  • Confirm the required charge quantity and valve connection.

Transfer R407A from the cylinder in the liquid phase and use dew-point or bubble-point data as appropriate.

  • Meter liquid safely to prevent compressor damage.
  • Account for temperature glide during superheat and subcooling checks.
  • Do not mix with another refrigerant.

Follow the equipment or retrofit manufacturer's instructions and the product Safety Data Sheet.

  • Confirm lubricant compatibility and operating setpoints.
  • Store the cylinder in a cool, dry, ventilated area.
  • Review the Shipping & Returns tab before ordering.

Planning an R407A retrofit? Send support the current refrigerant, equipment model, application, and operating temperature range.

Frequently Asked Questions

Use R407A only when the equipment manufacturer or an approved retrofit specification calls for R407A. Do not add it directly on top of R22, R404A, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.

R407A refrigerant blend is intended for compatible commercial refrigeration and low-temperature equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.

The cylinder contains 25 lb (11.3 kg) net weight of R407A refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.

No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.

System conversion or charging decisions should be made by a qualified refrigeration professional after checking the equipment, lubricant, controls, and manufacturer requirements. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.

Shipping is free on U.S. orders. Orders ship from the United States within 24 business hours, and estimated delivery is 2–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.

Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.

A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer's responsibility, and refunds are issued after inspection.

Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.

You may also need

Related products

Customer Reviews

5.00 out of 5Based on 1 review
1
0
0
0
0
1 review
08/19/2026
Priscilla M. Verified Buyer

Quick, easy delivery and pricing was affordable.